i)
CONTINUOUSLY
VARIABLE (CV-CL) OR (CV-CC) POWER SUPPLIES

|
* FEATURES
:
| * |
Output
voltage adjustable from 0 to specified voltage. |
| * |
Current
limit adjustable from 5% to 110% of specified load
current. |
| * |
Two
completely isolated outputs - can be configured in
series or parallel to enhance voltage or current output
capacity respectively. |
| * |
Load
& line regulation : +/-0.05% max. |
| * |
Ripple
& noise : 1mv (r.m.s.) max. |
| * |
Protected
against overload & short circuit. |
| * |
Continuous
metering of output voltage & current. |
| * |
Input
voltage 230V Ac +/-10%, 50Hz, single phase or more wide
range. |
| * |
Operating
temperature range : 0 to 500C. |
| * |
Remote
sensing for distantly situated loads for models above 5
Amps. |
* OPTIONAL
FACILITIES :
| * |
Over
voltage protection ( fixed / variable ) |
| * |
Input
voltage : 115 V AC +/-10% or more wide range. |
| * |
Rack-mounting,
wall mounting, base mounting. |
| * |
TTL
compatible active on/off. |
|
ii)
' POWER SUPPLIES FOR LINEAR IC CIRCUITS' (DUAL TRACKING)
FEATURES :
* Fixed
Output Voltage (settable plus +/-10% of nominal output voltage)
* Preset Positive and Negative Outputs Employing Master / Slave
Technique.
* Tracking Accuracy : +/-1%, Load & Line Regulation L +/-0.1%
* Ripple & Noise : 1mv (r.m.s.) max.
* Protected Against Overload & Short Circuit.
* Input Voltage : 230V AC +/-10%, 50Hz, Single Phase or more wide range.
* Operating Temperature : 0 to 500C.
OPTIONAL
FACILITIES :
*
Metering of Output Voltage &/or Current.
* Over Voltage Protection.
* Input Voltage : 115V AC +/-10% or more wide range.
* Rack-Mounting, Wall Mounting, Base Mounting
* TTL Compatible Active ON/OFF.
FIXED OUTPUT
POWER SUPPLIES :
* Fixed
DC Voltage Output (settable over +/-10% of nominal is optional ).
* Factory Set Current Limit (adjustable optional).
* Load & Line Regulation : +/-0.5% to 0.05%
* Ripple & Noise : 1 mv (r.m.s.) max.
* Protected Against Overload &
Short Circuit.
* Crowbar Type Over Voltage protection.
* Protection at Output ( for, above 5V output unit. )
* Remote Sensing for Distantly Situated Loads for Models above 5 Amp.
* Input Voltage : 230V AC +/-10%, 50Hz, single phase or more wide range.
* Operating Temperature : 0 to 500C.
OPTIONAL FACILITIES :
* Metering of Output
Voltage &/or Current.
* Input Voltage : 115V AC +/-10% or more wide range.
* Over Voltage Protection.
* Rack-Mounting, Wall Mounting, Base Mounting.
* TTL Compatible Active ON/OFF.
iii)
S.M.P.S
SWITCH
MODE POWER SUPPLIES
FEATURES :
* Preset O/P
Voltage (+/-5% Adjustable)
* Load & Line Regulation : +/-0.2%
* Ripple : 1% P.P. max. r.m.s.
* Noise : 2% P.P. max. r.m.s.
* Wider Supply Voltage : 176-264V AC, 47-54 Hz,
1Phase
(90-280 V AC single phase also
available ).
* Overload & Short Circuit Protection.
* Output Over-Voltage Protection.
* Remote Sensing at Output.
* Carry-over Time min.20 ms.
* Operating Temp. : 0-500C
OPTIONAL FACILITIES :
* Multi Output
Configuration (Max. Three Outputs ).
* Rack Mounting / DIN Rail Mounting.
* SMPS Based Battery Charges.
* Digital Display For Voltage / Current
* Built-in RFI Suppression.
IV) HIGH
CURRENT / HIGH POWER RECTIFIERS
|

High
Current / High Power Rectifiers
|
FEATURES :
* Continuous
Duty Operation.
* Overload / Short Circuit Protection with Indication.
* Over Voltage Protection with Indication.
* Under Voltage Protection with Indication.
* Regulation +/-1%
* Ripple : 1% r.m.s. maximum.
* Digital Display for output voltage & current.
OPTIONAL FACILITIES :
* Process
complete timer with visual indication & alarm
* Timer with reset & do not count time ( Time
hold feature ) during
mains failure.
* Ampere hour meter.
APPLICATIONS :
* Electro
plating
* Water treatment etc.
|
|
|