Power Supplies


* Output voltage adjustable from 0 to specified voltage.
* Current limit adjustable from 5% to 110% of specified load current.
* Two completely isolated outputs - can be configured in series or parallel
   to enhance voltage or current output capacity respectively.
* Load & line regulation : +/-0.05% max.
* Ripple & noise : 1mv (r. m. s.) max.
* Protected against overload & short circuit.
* Continuous metering of output voltage & current.
* Input voltage 230V Ac +/-10%, 50Hz, single phase or more wide range.
* Operating temperature range : 0 to 500C.
* Remote sensing for distantly situated loads for models above 5 Amps.

* Over voltage protection ( fixed / variable )
* Input voltage : 115 V AC +/-10% or more wide range.
* Rack-mounting, wall mounting, base mounting.
* TTL compatible active on/off.
 

* Fixed Output Voltage (settable  +/-10% of nominal output voltage)
* Preset Positive and Negative Outputs Employing Master / Slave Technique.
* Tracking Accuracy : +/-1%, Load & Line Regulation L +/-0.1%
* Ripple & Noise : 1mv (r.m.s.) max.
* Protected Against Overload & Short Circuit.
* Input Voltage : 230V AC +/-10%, 50Hz, Single Phase or more wide range.
* Operating Temperature : 0 to 500C.

* Metering of Output Voltage &/or Current.
* Over Voltage Protection.
* Input Voltage : 115V AC +/-10% or more wide range.
* Rack-Mounting, Wall Mounting, Base Mounting
* TTL Compatible Active ON/OFF.

* Fixed DC Voltage Output (settable over +/-10% of nominal is optional ).
* Factory Set Current Limit (adjustable optional).
* Load & Line Regulation : +/-0.5% to 0.05%
* Ripple & Noise : 1 mv (r.m.s.) max.
* Protected Against Overload & Short Circuit.
* Crowbar Type Over Voltage protection.
* Protection at Output ( for, above 5V output unit. )
* Remote Sensing for Distantly Situated Loads for Models above 5 Amp.
* Input Voltage : 230V AC +/-10%, 50Hz, single phase or more wide range.
* Operating Temperature : 0 to 500C.

* Metering of Output Voltage &/or Current.
* Input Voltage : 115V AC +/-10% or more wide range.
* Over Voltage Protection.
* Rack-Mounting, Wall Mounting, Base Mounting.
* TTL Compatible Active ON/OFF.
 

* Preset O/P Voltage (+/-5% Adjustable)
* Load & Line Regulation : +/-0.2%
* Ripple : 1% P.P. max. r.m.s.
* Noise : 2% P.P. max. r.m.s.
* Wider Supply Voltage : 176-264V AC, 47-54 Hz, 1Phase (90-280 V AC single phase also available ).
* Overload & Short Circuit Protection.
* Output Over-Voltage Protection.
* Remote Sensing at Output.
* Carry-over Time min.20 ms.
* Operating Temp. : 0-500C

*  Multi Output Configuration (Max. Three Outputs ). 
*  Rack Mounting / DIN Rail Mounting.
*  SMPS Based Battery Charges.
*  Digital Display For Voltage / Current
*  Built-in RFI Suppression.

* Continuous Duty Operation.
* Overload / Short Circuit Protection with Indication.
* Over Voltage Protection with Indication.
* Under Voltage Protection with Indication.
* Regulation +/-1%
* Ripple : 1% r.m.s. maximum.
* Digital Display for output voltage & current.

* Process complete timer with visual indication & alarm
* Timer with reset & do not count time ( Time hold feature ) during mains failure.
* Ampere hour meter.

* Electro plating
* Water treatment etc.


Home  | Products | High Voltage Test Set  | Oil Test Sets  | Current Injector  |  Voltage Stabilizer |
 | Inverters  | UPS  |  Power Supplies  | Battery Chargers  | DC-DC Converters  | Transformers  Profile | Contact | Enquiry

 

Designed & Hosted by : MIDD   Promoted by : GID