Inverters

  • Longer and Continuous back up time : Back up time available from 20 minutes to
    several hours with increasing number of batteries.

  • Regulated Battery Charger-Low Running Cost. Ensures longer life of battery : We provide boost / float cum trickel charger which avoides the excess charging. Thereby avoiding boiling of battery water, which inturn saves electricity & reccuring maintaince of battery.

  • Latest Switching Technology-Higher Efficiency : The inverter controller is either open loop or close loop pulse width modulator with 6.8 kHz carrier frequency which gives us the higher efficiency.

  • Separate Transformers for Inverter and Charger - ensures longer life of Unit : We avoide using same transformer as inverter transformer & charger transformer.  We separately provide two different sections such as inverter section & charger section.  Inverter section mainly consist of switching circuit transformer & power device.  The charger section in either smps type or linear power supply type or thyristor controlled type depending upon the capacity & type of battery where the transformer is separate from that of inverter section.

  • Very Compact in Size : With great experience in this field & continuous research in the same field.  We always use new & latest technology by which we can always provide compact units to our customers.

  • By-pass Mode : This mode is provided on demand as to give additional facility to bypass the system from the main supply as and when required for maintaince purpose.

  • Front panel LED indication - mains ON, Inverter ON, Battery low & Overload : Mains on : Visual indication for mains supply.
    Inverter on : Visual indication when inverter is ON ( Mains Fail )
    Battery Low : Visual indication for battery low
    Overload : Visual indication when inverter is overloaded.

  • Overload protection : This facility is provided for protecting inverter from getting overloaded.  In this cases first unit will go on current limit mode & even if the overload persist it immediately trips off.

  • Dead short circuit protection : This is optional protection.

  • Input and Output protected by fuses : Provided to get protected form over current.
                                                    

Technical Specification

Capacity 

200 VA onwards

Input A.C. Range

130 V-300 VAC 1 PH 50 Hz

Input D.C- Range

10.5V-14.2V or in multiples of the same

Wave form

Quazi Wave / Modified Sine Wave / Pure Sine Wave

Output Frequency

50 Hz + /- 0.1% or 60 Hz + /-0.1% or as per requirement.

Efficiency on Battery

> 92%

Overload Protection

110%

Short Circuit Protection

300%

Charger

Constant Voltage / Constant Current Mode & Trickel Charger 

Specifications are subject to change without prior notice

NORMAL LOAD SELECTION CHART( For selecting your inverter Model)

APPLIANCE TYPE

APPROX. CONSUMPTION

APPLIANCE TYPE

APPROX. CONSUMPTION RATING

Tube light 

55 VA

Ceiling Fan

85 VA

Colour TV 100 VA Mixer 500 VA
Computer 250 VA Laser Printer 300 VA
VCR 50 VA Table Fan 100 VA
Fax 50 VA Stereo 100 VA
Printer 200 Va EPABX Actual VA

|   Inverter  |  UPS  |  Voltage Stabilizer  |  Power Supplies  |  Battery Chargers  |  DC-DC Converters  |
|   Transformers   |  High Voltage Test Set  |  Other Products  |